| Classification | Z-15 (except micro load and flexible rod) | Z-01H | Z-15 (flexible rod) | Z-10F | Z-15H2 |
|---|
| Operating speed | 0.01 mm to 1 m/s *1 | 1 mm to 1 m/s | 0.1 mm to 1 m/s *1 | 0.01 mm to 1 m/s |
|---|
Operating frequency | Mechanical | 240 operations/min | 120 operations/min | 240 operations/min | 240 operations/min |
|---|
| Electrical | 20 operations/min |
|---|
| Insulation resistance | 100 MΩ min. (at 500 VDC) |
|---|
| Contact resistance | 15 mΩ max. (initial value) | 50 mΩ max. (initial value) | 15 mΩ max. (initial value) | 25 mΩ max. (initial value) | 15 mΩ max. (initial value) |
|---|
| Dielectric strength | Between contacts of same polarity Contact gap G: 1,000 VAC, 50/60 Hz for 1 min Contact gap H: 600 VAC, 50/60 Hz for 1 min Contact gap E: 1,500 VAC, 50/60 Hz for 1 min | Between contacts of same polarity Contact gap G: 1,000 VAC, 50/60 Hz for 1 min Contact gap H: 600 VAC, 50/60 Hz for 1 min | Between contacts of same polarity Contact gap F: 1,500 VAC, 50/60 Hz for 1 min | Between contacts of same polarity 600VAC, 50/60Hz for 1 min |
|---|
| Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude * 5 | 10 to 20 Hz, 1.5-mm double amplitude *5 | 10 to 55 Hz, 1.5-mm double amplitude *5 |
|---|
Shock resistance | Destruction | 1,000 m/s2 max. |
|---|
| Malfunction | 300 m/s2 max. *2 *5 | 50 m/s2 max. *5 | 300 m/s2 max. *3 *5 | 100 m/s2 max. |
|---|
| Durability | Mechanical | Contact gap G, H: 20,000,000 operations min. Contact gap E: 300,000 operations | 1,000,000 operations min. | 500,000 operations min. *1 | 20,000,000 operations min. |
|---|
| Electrical | Contact gap G, H: 500,000 operations min. Contact gap E: 100,000 operations min. | 100,000 operations min. | 100,000 operations min. | 500,000 operations min. |
|---|
Degree of protection | General- purpose | IP00 |
|---|
| Drip-proof | Equivalent to IP62 (except terminals) |
|---|
Degree of protection against electric shock | Class I |
|---|
Proof tracking index (PTI) | 175 |
|---|
Ambient operating temperature | General- purpose | – 25 °C to 80 °C (with no icing) |
|---|
| Drip-proof | – 15 °C to 80 °C (with no icing) |
|---|
Ambient operating humidity | General- purpose | 35% to 85%RH |
|---|
| Drip-proof | 35% to 95%RH |
|---|
| Weight | Approx. 22 to 58 g | Approx. 42 to 48 g | Approx. 34 to 61 g | Approx. 22 g |
|---|