Classification | Z-15 (except micro load and flexible rod) | Z-01H | Z-15 (flexible rod) | Z-10F | Z-15H2 |
---|
Operating speed | 0.01 mm to 1 m/s *1 | 1 mm to 1 m/s | 0.1 mm to 1 m/s *1 | 0.01 mm to 1 m/s |
---|
Operating frequency | Mechanical | 240 operations/min | 120 operations/min | 240 operations/min | 240 operations/min |
---|
Electrical | 20 operations/min |
---|
Insulation resistance | 100 MΩ min. (at 500 VDC) |
---|
Contact resistance | 15 mΩ max. (initial value) | 50 mΩ max. (initial value) | 15 mΩ max. (initial value) | 25 mΩ max. (initial value) | 15 mΩ max. (initial value) |
---|
Dielectric strength | Between contacts of same polarity Contact gap G: 1,000 VAC, 50/60 Hz for 1 min Contact gap H: 600 VAC, 50/60 Hz for 1 min Contact gap E: 1,500 VAC, 50/60 Hz for 1 min | Between contacts of same polarity Contact gap G: 1,000 VAC, 50/60 Hz for 1 min Contact gap H: 600 VAC, 50/60 Hz for 1 min | Between contacts of same polarity Contact gap F: 1,500 VAC, 50/60 Hz for 1 min | Between contacts of same polarity 600VAC, 50/60Hz for 1 min |
---|
Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude * 5 | 10 to 20 Hz, 1.5-mm double amplitude *5 | 10 to 55 Hz, 1.5-mm double amplitude *5 |
---|
Shock resistance | Destruction | 1,000 m/s2 max. |
---|
Malfunction | 300 m/s2 max. *2 *5 | 50 m/s2 max. *5 | 300 m/s2 max. *3 *5 | 100 m/s2 max. |
---|
Durability | Mechanical | Contact gap G, H: 20,000,000 operations min. Contact gap E: 300,000 operations | 1,000,000 operations min. | 500,000 operations min. *1 | 20,000,000 operations min. |
---|
Electrical | Contact gap G, H: 500,000 operations min. Contact gap E: 100,000 operations min. | 100,000 operations min. | 100,000 operations min. | 500,000 operations min. |
---|
Degree of protection | General- purpose | IP00 |
---|
Drip-proof | Equivalent to IP62 (except terminals) |
---|
Degree of protection against electric shock | Class I |
---|
Proof tracking index (PTI) | 175 |
---|
Ambient operating temperature | General- purpose | – 25 °C to 80 °C (with no icing) |
---|
Drip-proof | – 15 °C to 80 °C (with no icing) |
---|
Ambient operating humidity | General- purpose | 35% to 85%RH |
---|
Drip-proof | 35% to 95%RH |
---|
Weight | Approx. 22 to 58 g | Approx. 42 to 48 g | Approx. 34 to 61 g | Approx. 22 g |
---|